|
DePuy Synthes
angular stable plates tomofix Angular Stable Plates Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/angular stable plates tomofix/product/DePuy Synthes Average 90 stars, based on 1 article reviews
angular stable plates tomofix - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
tomofix-locking plate fixation Tomofix Locking Plate Fixation, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/tomofix-locking plate fixation/product/DePuy Synthes Average 90 stars, based on 1 article reviews
tomofix-locking plate fixation - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
angle-stable implant tomofix plate Angle Stable Implant Tomofix Plate, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/angle-stable implant tomofix plate/product/DePuy Synthes Average 90 stars, based on 1 article reviews
angle-stable implant tomofix plate - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Synthes Ltd
long type locking plate Long Type Locking Plate, supplied by Synthes Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/long type locking plate/product/Synthes Ltd Average 86 stars, based on 1 article reviews
long type locking plate - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
|
DePuy Synthes
tomofix precontoured distal femoral locking plate Tomofix Precontoured Distal Femoral Locking Plate, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/tomofix precontoured distal femoral locking plate/product/DePuy Synthes Average 90 stars, based on 1 article reviews
tomofix precontoured distal femoral locking plate - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
tomofix medial high tibial plate Tomofix Medial High Tibial Plate, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/tomofix medial high tibial plate/product/DePuy Synthes Average 90 stars, based on 1 article reviews
tomofix medial high tibial plate - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Synthes Ltd
tomofix Tomofix, supplied by Synthes Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/tomofix/product/Synthes Ltd Average 86 stars, based on 1 article reviews
tomofix - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
|
DePuy Synthes
tomofix long and rigid t-shaped titanium internal fixator with uniaxial locking system ![]() Tomofix Long And Rigid T Shaped Titanium Internal Fixator With Uniaxial Locking System, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/tomofix long and rigid t-shaped titanium internal fixator with uniaxial locking system/product/DePuy Synthes Average 90 stars, based on 1 article reviews
tomofix long and rigid t-shaped titanium internal fixator with uniaxial locking system - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
tomofix plate tomofix osteotomy system ![]() Tomofix Plate Tomofix Osteotomy System, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/tomofix plate tomofix osteotomy system/product/DePuy Synthes Average 90 stars, based on 1 article reviews
tomofix plate tomofix osteotomy system - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
DePuy Synthes
anterointernal tomofix ![]() Anterointernal Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/anterointernal tomofix/product/DePuy Synthes Average 90 stars, based on 1 article reviews
anterointernal tomofix - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
|
Arthrex Inc
tomofix plate ![]() Tomofix Plate, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/tomofix plate/product/Arthrex Inc Average 86 stars, based on 1 article reviews
tomofix plate - by Bioz Stars,
2026-06
86/100 stars
|
Buy from Supplier |
|
DePuy Synthes
tomofix ![]() Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/tomofix/product/DePuy Synthes Average 90 stars, based on 1 article reviews
tomofix - by Bioz Stars,
2026-06
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Fixation devices compared by Maas et al. (Maas et al. ). ( a ) The ContourLock HTO plate is applicable to patients without weight limitation. ( b ) The TomoFix sm plate is indicated only for small stature patients
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Fixation devices compared during the last tests performed. ( a ) TomoFix std plate, ( b ) PEEKPower HTO plate and ( c ) iBalance HTO implant. All this implants are indicated with no weight restriction
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Specimen grouping and assignment, depending on the implants used and the tests performed
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Curves of the force versus the displacements in cases of TomoFix std1. The final rupture of the specimen occurred quite promptly after the crack formations, which were characterized by a drop in the registered applied force. The crack and the ultimate loads were considered as the approximate loads at the moment the crack formations and collapse of the contralateral cortex occurred respectively
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Curves of the force versus the displacements in cases of PEEKPower 2. The final rupture of the specimen occurred quite promptly after the crack formations. The medial displacement (MS) was positive contrary to e.g. the TomoFix std 1
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Static tests summary: displacements, valgus malrotation of the tibial head and their corresponding cracks and ultimate loads, including mean values and standard deviations (SD)
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Hysteresis loops: lateral displacement (TomoFix 5 specimen). The higher the loads, the more the maximal displacement range within the loops grew but was never bigger than 0.5 mm
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Deflection angle or valgus malrotation of the tibial head before and after failure for groups 4 and 5 (the graph is retrieved from our previous study and showed here for sake of comparison). The TomoFix specimens here are the TomoFix small stature of group 4 in the present study
Article Snippet:
Techniques: Comparison
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Summary of fatigue failure tests (groups 1, 2 & 3): max. load, vertical & lateral stiffness, number of cycles (all values prior to failure) and failure types
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Summary of fatigue to failure tests (groups 4 & 5): max. load, vertical & lateral stiffness, number of cycles (all values prior to failure) and failure types
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Average mean values, including the standard deviations (SD) per group of the cyclic fatigue to failure tests (all decimal values rounded to the 1st decimal)
Article Snippet:
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy
doi: 10.1186/s40634-015-0030-4
Figure Lengend Snippet: Average relative strength values of Table . The TomoFix std group was taken as reference
Article Snippet:
Techniques:
Journal: International Journal of Surgery Case Reports
Article Title: Medial opening wedge high tibial osteotomy in patients with posttraumatic medial tibial plateau bone defect: A case report
doi: 10.1016/j.ijscr.2017.10.020
Figure Lengend Snippet: Case 2: (A) Meticulous deep soft tissue dissection was performed in the medial side of the left knee to expose the crater of the bone defect. (B) Horizontal dimension of the crater was 6 cm. (C) Vertical dimension of the crater was 3 cm. (D) Femoral head allograft was prepared to fit the medial bone defect. (E) Medial opening wedge high tibial osteotomy was performed with the allograft temporarily fixed in position using multiple Kirschner wires. (F) Remnant femoral head allograft was inserted into the osteotomy gap, and TomoFix plate was inserted to stabilize both the grafted proximal allograft and osteotomy site.
Article Snippet: Because the unfitting contour of the allograft was pushing the proximal locking holes of the
Techniques: Dissection
Journal: International Journal of Surgery Case Reports
Article Title: Medial opening wedge high tibial osteotomy in patients with posttraumatic medial tibial plateau bone defect: A case report
doi: 10.1016/j.ijscr.2017.10.020
Figure Lengend Snippet: Case 2: Fluoroscopic images showing the operative procedure. (A) Osteotomy level was determined with allograft and TomoFix plate located in virtual position. (B) Osteotomy gap was gradually distracted using the distractor. (C) Plate fixation was complete with allograft augmentation on the medial tibial defect and in the osteotomy gap. (D–F) Alignment correction was checked intraoperatively using metal rod.
Article Snippet: Because the unfitting contour of the allograft was pushing the proximal locking holes of the
Techniques:
Journal: Journal of Experimental Orthopaedics
Article Title: Effect of plate design on maintenance of anterior and posterior gaps and posterior tibial slope after cyclic loading in medial open‐wedge high tibial osteotomy: A biomechanical study using porcine's tibia
doi: 10.1002/jeo2.12036
Figure Lengend Snippet: Specimen preparation. (a) Specimen after MOWHTO with TOMOFIX applied to the right knee. (b) Specimen after MOWHTO with AC plate applied to the left knee. (c) Specimen after MOWHTO with TriS applied to the left knee. MOWHTO, medial open wedge high tibial osteotomy.
Article Snippet: We hypothesized that the TriS and AC plates would provide maintenance of AG, PG and PTS compared with the anterointernal
Techniques: